Item Name: FLUKE F117C Digital Electrician Multimeter
USD 193.00
 
Item Code: 0023-0179
 Ask a question about this
 
 Add my watch 1
 

FLUKE F117C Digital Electrician Multimeter

  Description
 

0023-0179
FLUKE F117C ELECTRICIAN MULTIMETER



I.Feature:
 

  • VoltAlert technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak) for hands free operation
  • CAT III 600 V safety rated

II.Specification:

 

Specifications
Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
   11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61(NOT INCUDING BATTERY)
Battery Life
   400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
   20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
   20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 

 

Photo will have chromatic aberration compared with the product

 

 

PACKAGE CONTAIN

1 x FLUKE 117C Digital Multimeter;
1 x Fluke of test leads ;
1 x Operation manual in English

(NOT INCUDING BATTERY)

C

 

 
 


Shipping Address Notice


Turkey & Belgium
Customs Notice


ELECTRIC METER

Cable Tester
Clamp Current Meter
Distance Measurer
Multimeter (Analog)
 
Oscilloscope
 
Hight Accuracy Meters
     
Lux /Light Meter
     
Moisture Tester
   
Radiation Detector
     
Resistance Testers
       
Sound level Meter
       
Tachometers meter
 
Voltage Detectors
 
Weather Meter
 
Energy saving lamps tester
       
SMD Tester
       
Battery Tester
     
Other Tester
 
Test Lead /Probe
UTL02.jpg (120×160)
UTL03.jpg (120×160) UT-L13.jpg (120×160) UTL19.jpg (120×160) UTL23.jpg (120×160) UT-P03.jpg (120×160)
UT-P04.jpg (120×160) UT-P05.jpg (120×160) UT-D04.jpg (120×160) UT-D04.jpg (120×160)  

537

 
TOP
 

Copyright © 2017 409shop walkie talkie All Rights Reserved.    
Surecom_product-line 409shop-site-map 409shop-site-map
Our Company Products Learn & Support Customer Service Partner With Us
Home 2017 COMING SOON  Software Downloads PAY Method Reseller Contact
About Us LED  Technical Support Post Tracking Supplier Contact
My Company DMR Radio FRS Frequency Privacy Policy Affiliate Program
News  Small Mobile FAQ Repair Return Address 寻求供应商
Authority of All   Exchange/Refund/Return Policy Contact Us  